COMPLIANCE STATEMENT to EEC Low Voltage Directive 73/23 (EN 61058-1 standard) We list below the data required by table 2 of the standard above. Further data are specified in the catalogue. |
| Table's | Matter | Assigned value |
| head |   |
|
| 1. |
IDENTIFICATION | |
| - manufacturer's name | PALAZZO Componenti Elettronici | |
| - model | 10R111NS 10R206NS 10R304NS 10R403NS | |
| |
10R111S 10R206S 10R304S 10R403S |
|
| 2. | SWITCHING ENVIRONMENT, USING | |
| - protection level against | Protect the component from electrical contacts | |
| external electric shock. | during assembling operations. | |
| This product is suitable for class 1 sets | ||
| provided with ground connection. | ||
| 2.3 | MOUNTING SYSTEMS | Fitting to the front panel by exagonal nut and/or |
| by soldering on the printed circuit board. | ||
| 3. | TEMPERATURE | operating range: -20 +80°C |
| 4. | ELECTRIC LOAD | Current breaking capacity(resistive load): |
| 200mA 250Vac - 300mA 110Vac - 400mA 30Vdc | ||
| 5. | CONNECTIONS | |
| - type of admitted conductors | Rigid conductors (PCB tracks) minimum section 0,015mm˛ | |
| - soldering systems | Manual or machinery processing. | |
| The switch must be protect from contact | ||
| with soldering flush and from the following washing. | ||
| 6. | OPERATING CYCLES / SEQUENCY | 100.000 |
| 8. | CIRCUIT BREAKING | Limited breaking |
| 9. | INSULATORS TRACKING INDEX (PTI) | 425 |
| - heat and fire resistance class | 650° white-hot thread test on insulating parts | |
| that holds contacts under voltage. | ||
| The test report TO397 dated 13/03/97 was issued by CESVIT-CETACE, SIT 56 center. This laboratory was licenced for Low Voltage Directive tests, by a Decree dated 20/05/94 signed by te Italian Ministry of Industry. The laboratory works togheter with the Department of Electronics at the University of Florence. The complete test report is available on Customers' demand. |